OXIBOY HME Filter: Features, Patient Sizes & Buying Guide
Information Lubdub Bazaar
Heat and moisture exchange filters are used in respiratory and anaesthesia care, where selecting the correct device for the patient and breathing system is important. For hospital procurement teams, ICU staff, and biomedical engineers, the key checks include patient suitability, connection requirements, and documented performance specifications.
The OXIBOY Heat and Moisture Exchange Filter is intended for airway management by anaesthesia and respiratory-care departments. The supplied product information lists adult, paediatric, and neonatal options.
This guide explains its listed construction and the specifications to confirm before ordering.
What Is a Heat and Moisture Exchange Filter?
A heat and moisture exchanger, commonly called an HME, is designed to conserve some of the heat and moisture in exhaled breath and return it during subsequent inhalation. An HME filter combines this function with filtration media.
Performance varies between devices. Buyers should review model-specific documentation rather than assuming that every HME filter provides the same humidification or filtration performance.
OXIBOY HME Filter Features
Polypropylene Outer Body
The supplied specifications identify polypropylene as the outer-body material. The housing contains the filter media and forms part of the connection within the intended breathing setup.
Confirm the connector dimensions and compatibility with the breathing circuit before purchase. The supplied information does not establish connector sizes.
Electrostatic Filter Media
The listed filter medium is electrostatic filter paper.
However, the material description alone does not establish bacterial or viral filtration efficiency. If your facility requires a particular filtration performance, request the manufacturer’s model-specific test data before approving the product.
Adult, Paediatric and Neonatal Options
The supplied information lists three patient categories: adult, paediatric, and neonatal.
These options should not be treated as interchangeable. Confirm each model’s labelled patient range, recommended tidal-volume range, internal volume or apparatus dead space, and resistance to airflow.
These checks are particularly important when selecting a device for patients receiving small tidal volumes. Follow the manufacturer’s instructions and the responsible clinician’s assessment.
Dimensions and Packaging
The supplied dimensions are 6.3 cm in length and 7.6 cm in width. Confirm which model these measurements apply to and whether they describe the device or its packaging.
The packing material is listed as an LDPE poly bag, and the product is described as non-sterilized. Packaging alone should not be taken as evidence of sterility.
What Does the ISO 9360-1 Reference Mean for Buyers?
The supplied product name references ISO 9360-1. Buyers should request documentation explaining the applicable standard, tested model, and reported performance.
A standard reference in a product description should not be treated as independent proof of certification or evidence that every adult, paediatric, and neonatal variant has identical performance.
HME Filter vs Breathing Filter: What Should You Check?
When comparing products, distinguish between heat-and-moisture exchange performance and filtration performance.
A product described as a breathing filter should not automatically be assumed to provide humidification. Likewise, an HME description alone does not establish a particular level of bacterial or viral filtration.
For the OXIBOY model you intend to purchase, request documented moisture-loss or humidification performance, filtration efficiency, airflow resistance, and internal volume. These values are not included in the supplied specifications.
Compatibility With the Respiratory Setup
An HME filter must be selected for the complete respiratory setup, not simply because its connectors appear to fit.
Confirm compatibility with the intended ventilator or anaesthesia breathing system, patient interface, and humidification arrangement. Placement and use should follow the equipment and filter manufacturers’ instructions.
Do not assume an HME filter should be combined with an active heated humidifier. Have the clinical team confirm the appropriate humidification configuration.
Shelf Life, Storage and Replacement
The supplied shelf-life field states “NIL.” This should not be interpreted as an unlimited shelf life or indefinite permission to use the product.
Before ordering, request clarification of the applicable shelf life, expiry labelling, storage conditions, and packaging requirements.
Also confirm whether the exact model is single-use or single-patient use, its maximum permitted duration of use, and the conditions requiring earlier replacement. Do not infer a replacement schedule from the product name alone.
Choosing the Right OXIBOY HME Filter
For a clear purchase enquiry, specify the patient category, required quantity, intended breathing system, and any performance requirements set by your facility.
Ask for the exact catalogue number and supporting documentation covering patient suitability, connector dimensions, filtration efficiency, humidification performance, airflow resistance, and internal volume.
This information helps procurement teams compare like-for-like products instead of relying on size labels or price alone.
Explore the OXIBOY Adult HME Filter
For adult product enquiries, view the
For paediatric or neonatal requirements, include the patient category and breathing-system details in your enquiry so the appropriate model specifications can be confirmed.
Use the selected device only according to the manufacturer’s instructions and your facility’s clinical protocols.